DM Class 1750
FL# 47754.2
1¾” Snaplock (18” Wide)
.032”, .040”, or .050” Aluminum
Approved
Approved for installation inside and outside of the HVHZ (Miami-Dade & Broward counties)
Installation
*Be sure to review the installation notes included in the Evaluation Report document.
Underlayment
Comply with FBC 1507.1.1 (non-HVHZ) or 1518.2 (HVHZ), and per local codes.
Slope
Comply with FBC 1507.4.2 (non-HVHZ) or 1515.2 (HVHZ), and per local codes. OUTSIDE the HVHZ, FBC 1507.4.2 minimum slope is 1/4:12.
INSIDE the HVHZ, FBC 1515.2 minimum slope is 2:12.
Trim and Flashing Details
Comply with manufacturer’s recommendations and RAS 133.
Fire Barrier
Comply with FBC 1516.1 and 1516.2 where required. Where not required by code. Fire classification is not a part of this evaluation. Where required, refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly.
Panel Labeling
Products sold in the HVHZ that require labeling shall bear the following or similar label. Other labeling in accordance with FBC 1523.5 shall also be permitted.
Contact Sales
Call us
(772) 577 1546




